Radiation shielding properties of transparent erbium zinc tellurite glass system determined at medical diagnostic energies SA Tijani, SM Kamal, Y Al-Hadeethi, M Arib, MA Hussein, S Wageh, ... Journal of Alloys and Compounds 741, 293-299, 2018 | 142 | 2018 |
A methodology for TLD postal dosimetry audit of high-energy radiotherapy photon beams in non-reference conditions J Iżewska, D Georg, P Bera, D Thwaites, M Arib, M Saravi, K Sergieva, ... Radiotherapy and oncology 84 (1), 67-74, 2007 | 82 | 2007 |
A multinational audit of small field output factors calculated by treatment planning systems used in radiotherapy W Lechner, P Wesolowska, G Azangwe, M Arib, VGL Alves, L Suming, ... Physics and Imaging in Radiation Oncology 5, 58-63, 2018 | 57 | 2018 |
Testing the methodology for dosimetry audit of heterogeneity corrections and small MLC-shaped fields: Results of IAEA multi-center studies J Izewska, P Wesolowska, G Azangwe, DS Followill, DI Thwaites, M Arib, ... Acta Oncologica 55 (7), 909-916, 2016 | 27 | 2016 |
Intercomparison 2013 on measurements of the personal dose equivalent Hp(10) in photon fields in the African region M Arib, A Herrati, F Dari, J Ma, Z Lounis-Mokrani Radiation Protection Dosimetry 163 (3), 276-283, 2015 | 17 | 2015 |
Establishment of ISO 4037-1 X-ray narrow-spectrum series at SSDL of Algiers A Herrati, M Arib, T Sidahmed, K Khalal-Kouache Radiation protection dosimetry 174 (1), 35-52, 2017 | 15 | 2017 |
Study of the influence of phantom material and size on the calibration of ionization chambers in terms of absorbed dose to water M Arib, T Medjadj, Y Boudouma Journal of Applied Clinical Medical Physics 7 (3), 55-64, 2006 | 11 | 2006 |
Optimum parameters of TLD100 powder used for radiotherapy beams calibration check M Arib, A Yaich, A Messadi, F Dari Medical Dosimetry 31 (3), 184-189, 2006 | 10 | 2006 |
Guidelines for the preparation of a quality manual for external audit groups on dosimetry in radiotherapy J Izewska, M Arib, M Saravi | 8 | 2002 |
A multinational audit of small field output factors calculated by treatment planning systems used in radiotherapy. Phys Imaging Radiat Oncol. 2018; 5: 58–63 W Lechner, P Wesolowska, G Azangwe, M Arib, VGL Alves, L Suming, ... | 7 | |
Initial Experiences in Testing The IAEA/AAPM Code of Practice on Small Field Dosimetry W Lechner, M Arib, P Ballesteros‐Zebadúa, K Christaki, P Francescon, ... International Conference on Advances in Radiation Oncology (ICARO-2), Vienna …, 2017 | 4 | 2017 |
Dosimetric Study of Heat-Treated Calcium–Aluminum–Silicon Borate Dosimeter for Diagnostic Radiology Applications I Algain, M Arib, SAF Al-Said, H Donya Sensors 23 (2), 1011, 2023 | 3 | 2023 |
A multi‐institutional evaluation of small field output factor determination following the recommendations of IAEA/AAPM TRS‐483 W Lechner, R Alfonso, M Arib, MS Huq, A Ismail, R Kinhikar, ... Medical Physics 49 (8), 5537-5550, 2022 | 3 | 2022 |
A quality assurance programme in dosimetry for Algeria: from simple to complex M Arib, S Khoudri, MS Bali, A Yennoune, A Toutaoui, F Dari, A Yaiche, ... | 3 | 2010 |
Calibration of plane parallel ionization chambers: a new service for secondary standard dosimetry laboratories? M Arib, H Chekerker, S Benmokhtar, A Meghzifene Medical Dosimetry 26 (4), 301-304, 2001 | 3 | 2001 |
Small field output factor measurement and verification for CyberKnife robotic radiotherapy and radiosurgery system using 3D polymer gel, ionization chamber, diode, diamond and … MA Al Kafi, M Arib, A Al Moussa, F Alzorkany, M Shehadeh, MFM Yusof, ... Applied Radiation and Isotopes 192, 110576, 2023 | 2 | 2023 |
A comprehensive quality assurance Program for radiotherapy using TLD: The Algerian Experience M Arib, T Medjadj, F Dari, MS Bali, S Khoudri, A Yennoune, B Hattali World Congress on Medical Physics and Biomedical Engineering, September 7-12 …, 2009 | 2 | 2009 |
Identification of Activation Isotopes in a CS-30 Cyclotron Vault AA Abuhoza, HA Kassim, AA Alghamdi, FM Alrumayan, M Arib, ... Sensors 22 (7), 2581, 2022 | 1 | 2022 |
IAEA-SSDL bilateral comparisons for diagnostic level air kerma measurement standards I Csete, P Toroi, A Steuer, C Hourdakis, F Gabris, S Jozela, A Kosunen, ... Physica Medica 47, 9-15, 2018 | 1 | 2018 |
Effect of background and transport dose on the results of the personal dose equivalent Hp(10) measurements in photon fields obtained during the intercomparison … M Arib, A Herrati, F Dari, Z Lounis-Mokrani Radiation protection dosimetry 167 (4), 399-404, 2015 | 1 | 2015 |