Compressed sensing: A simple deterministic measurement matrix and a fast recovery algorithm A Ravelomanantsoa, H Rabah, A Rouane IEEE Transactions on Instrumentation and Measurement 64 (12), 3405-3413, 2015 | 170 | 2015 |
Dielectric properties of blood: an investigation of haematocrit dependence F Jaspard, M Nadi, A Rouane Physiological measurement 24 (1), 137, 2003 | 137 | 2003 |
A four-electrode low frequency impedance spectroscopy measurement system using the AD5933 measurement chip C Margo, J Katrib, M Nadi, A Rouane Physiological measurement 34 (4), 391, 2013 | 90 | 2013 |
Non-invasive glycaemia blood measurements by electromagnetic sensor: study in static and dynamic blood circulation M Gourzi, A Rouane, R Guelaz, MS Alavi, MB McHugh, M Nadi, P Roth Journal of medical engineering & technology 29 (1), 22-26, 2005 | 74 | 2005 |
Simple and Efficient Compressed Sensing Encoder for Wireless Body Area Network A Ravelomanantsoa, H Rabah, A Rouane Instrumentation and Measurement, IEEE Transactions on 63 (Issue 12), 2973 - 2982, 2014 | 64 | 2014 |
Hyper-sensitive microwave sensor based on split ring resonator (SRR) for glucose measurement in water MA Zidane, A Rouane, C Hamouda, H Amar Sensors and Actuators A: Physical 321, 112601, 2021 | 43 | 2021 |
Study of a new electromagnetic sensor for glycaemia measurement: in vitro results on blood pig M Gourzi, A Rouane, R Guelaz, M Nadi, F Jaspard Journal of medical engineering & technology 27 (6), 276-281, 2003 | 32 | 2003 |
Validation of a methodology for determining the PEM fuel cell complex impedance modelling parameters A Bouaicha, H Allagui, EH Aglzim, A Rouane, A Mami International Journal of Hydrogen Energy 42 (17), 12738-12748, 2017 | 19 | 2017 |
An original method for non-invasive glucose measurement: preliminary results SM Alavi, M Gourzi, A Rouane, M Nadi 2001 Conference Proceedings of the 23rd Annual International Conference of …, 2001 | 18 | 2001 |
Design and implementation of a compressed sensing encoder: application to EMG and ECG wireless biosensors A Ravelomanantsoa, A Rouane, H Rabah, N Ferveur, L Collet Circuits, Systems, and Signal Processing 36, 2875-2892, 2017 | 14 | 2017 |
Microstrip sensor for product quality monitoring H Amar, H Ghodbane, M Amir, MA Zidane, C Hamouda, A Rouane Journal of Computational Electronics 19, 1329-1336, 2020 | 13 | 2020 |
An electronic measurement instrumentation of the impedance of a loaded fuel cell or battery EH Aglzim, A Rouane, R El-Moznine Sensors 7 (10), 2363-2377, 2007 | 13 | 2007 |
Parameters identification of the complex impedance model of the PEM fuel cell using Matlab/Simulink A Bouaicha, H Allagui, A Mami, EH Aglzim, A Rouane 2017 International Conference on Green Energy Conversion Systems (GECS), 1-6, 2017 | 11 | 2017 |
Four electrode embedded bioimpedance measurement system C Margo, J Katrib, M Nadi, A Rouane 2013 IEEE Faible Tension Faible Consommation, 1-4, 2013 | 9 | 2013 |
Study of an electronic load for measuring the internal impedance of a PEM fuel cell A Bouaicha, H Allagui, A Mami, A Rouane 10th International Multi-Conferences on Systems, Signals & Devices 2013 …, 2013 | 9 | 2013 |
New biosensor for non-invasive glucose concentration measurement M Gourzi, A Rouane, MB McHugh, R Guelaz, M Nadi SENSORS, 2003 IEEE 2, 1343-1347, 2003 | 9 | 2003 |
Design and realization of an electronic load for a PEM fuel cell A Bouaicha, H Allegui, A Rouane, EH Aglzim, A Mami International Journal of Electronics and Communication Engineering 8 (1 …, 2014 | 8 | 2014 |
Impedance spectrometer modelling in matlab/simulink for measuring the complex impedance of a fuel cell–EIS method EH Aglzim, MB Jamaluddin, D Chrenko, A Rouane Journal of Clean Energy Technologies 1 (4), 255-259, 2013 | 8 | 2013 |
Indirect method of non invasive in-vitro measurement of D+ glucose A Rouane Sensors & Transducers 93 (6), 69-81, 2008 | 8 | 2008 |
Hardware and software implementation for an auto-calibrated measurement system M Kouider, M Nadi, D Kourtiche, JP Olivarez, A Rouane SENSORS, 2003 IEEE 1, 611-616, 2003 | 8 | 2003 |