Entangling different-color photons via time-resolved measurement and active feed forward TM Zhao, H Zhang, J Yang, ZR Sang, X Jiang, XH Bao, JW Pan Physical Review Letters 112 (10), 103602, 2014 | 66 | 2014 |
Dual-ended readout small animal PET detector by using 0.5 mm pixelated LYSO crystal arrays and SiPMs Z Kuang, X Wang, X Fu, N Ren, Q Yang, B Zhao, C Zhang, S Wu, Z Sang, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2019 | 53 | 2019 |
Development of depth encoding small animal PET detectors using dual‐ended readout of pixelated scintillator arrays with Si PM s Z Kuang, Z Sang, X Wang, X Fu, N Ren, X Zhang, Y Zheng, Q Yang, Z Hu, ... Medical physics 45 (2), 613-621, 2018 | 42 | 2018 |
Obtaining PET/CT images from non-attenuation corrected PET images in a single PET system using Wasserstein generative adversarial networks Z Hu, Y Li, S Zou, H Xue, Z Sang, X Liu, Y Yang, X Zhu, D Liang, H Zheng Physics in Medicine & Biology 65 (21), 215010, 2020 | 40 | 2020 |
Design and performance of SIAT aPET: a uniform high-resolution small animal PET scanner using dual-ended readout detectors Z Kuang, X Wang, N Ren, S Wu, J Gao, T Zeng, D Gao, C Zhang, Z Sang, ... Physics in Medicine & Biology 65 (23), 235013, 2020 | 39 | 2020 |
Performance of a SiPM based semi-monolithic scintillator PET detector X Zhang, X Wang, N Ren, Z Kuang, X Deng, X Fu, S Wu, Z Sang, Z Hu, ... Physics in Medicine & Biology 62 (19), 7889, 2017 | 31 | 2017 |
Performance comparison of two signal multiplexing readouts for SiPM-based pet detector Q Yang, Z Kuang, Z Sang, Y Yang, J Du Physics in Medicine & Biology 64 (23), 23NT02, 2019 | 28 | 2019 |
A GPU-accelerated fully 3D OSEM image reconstruction for a high-resolution small animal PET scanner using dual-ended readout detectors T Zeng, J Gao, D Gao, Z Kuang, Z Sang, X Wang, L Hu, Q Chen, X Chu, ... Physics in Medicine & Biology 65 (24), 245007, 2020 | 24 | 2020 |
Front-end electronic readout system for the Belle II imaging Time-Of-Propagation detector D Kotchetkov, O Hartbrich, M Andrew, M Barrett, M Bessner, V Bhardwaj, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2019 | 23 | 2019 |
Performance of long rectangular semi‐monolithic scintillator PET detectors X Zhang, X Wang, N Ren, B Hu, B Ding, Z Kuang, S Wu, Z Sang, Z Hu, ... Medical physics 46 (4), 1608-1619, 2019 | 23 | 2019 |
The effects of inter-crystal scattering events on the performance of PET detectors C Zhang, Z Sang, X Wang, X Zhang, Y Yang Physics in Medicine & Biology 64 (20), 205004, 2019 | 22 | 2019 |
Characterization of a serializer ASIC chip for the upgrade of the ATLAS muon detector J Wang, L Guan, Z Sang, JW Chapman, T Dai, B Zhou, J Zhu IEEE Transactions on Nuclear Science 62 (6), 3242-3248, 2015 | 20 | 2015 |
A depth-encoding PET detector that uses light sharing and single-ended readout with silicon photomultipliers Z Kuang, Q Yang, X Wang, X Fu, N Ren, Z Sang, S Wu, Y Zheng, X Zhang, ... Physics in Medicine & Biology 63 (4), 045009, 2018 | 13 | 2018 |
A thick semi-monolithic scintillator detector for clinical PET scanners C Zhang, X Wang, M Sun, Z Kuang, X Zhang, N Ren, S Wu, Z Sang, T Sun, ... Physics in Medicine & Biology 66 (6), 065023, 2021 | 11 | 2021 |
Performance of a depth encoding PET detector module using light sharing and single-ended readout with SiPMs Z Kuang, Q Yang, X Wang, X Fu, N Ren, S Wu, C Zhang, B Zhao, Z Sang, ... Physics in Medicine & Biology 64 (8), 085012, 2019 | 11 | 2019 |
High resolution detectors for whole-body PET scanners by using dual-ended readout Z Liu, M Niu, Z Kuang, N Ren, S Wu, L Cong, X Wang, Z Sang, C Williams, ... EJNMMI physics 9 (1), 29, 2022 | 9 | 2022 |
Performance of two depth-encoding dual-ended readout PET detectors based on SiPM arrays with the same pitch size and different active areas Q Yang, Z Sang, C Zhang, J Du Journal of Instrumentation 15 (11), T11003, 2020 | 9 | 2020 |
Few-view CT image reconstruction using improved total variation regularization K Li, Z Sang, X Zhang, M Zhang, C Jiang, Q Zhang, Y Ge, D Liang, ... Journal of X-ray Science and Technology 27 (4), 739-753, 2019 | 9 | 2019 |
Ultra‐high‐resolution depth‐encoding small animal PET detectors: using GAGG and LYSO crystal arrays M Niu, Z Liu, Z Kuang, X Wang, N Ren, Z Sang, S Wu, L Cong, T Sun, ... Medical Physics 49 (5), 3006-3020, 2022 | 7 | 2022 |
A non-linearity correction method for fast digital multi-channel analyzers Z Sang, F Li, Y Yao, G Jin Physics Procedia 37, 1594-1599, 2012 | 7 | 2012 |