First MR images obtained during megavoltage photon irradiation from a prototype integrated linac‐MR system BG Fallone, B Murray, S Rathee, T Stanescu, S Steciw, S Vidakovic, ... Medical physics 36 (6Part1), 2084-2088, 2009 | 409 | 2009 |
Patient dosimetry for hybrid MRI‐radiotherapy systems C Kirkby, T Stanescu, S Rathee, M Carlone, B Murray, BG Fallone Medical physics 35 (3), 1019-1027, 2008 | 180 | 2008 |
A study on the magnetic resonance imaging (MRI)-based radiation treatment planning of intracranial lesions T Stanescu, HS Jans, N Pervez, P Stavrev, BG Fallone Physics in Medicine & Biology 53 (13), 3579, 2008 | 129 | 2008 |
Characterization of tissue magnetic susceptibility‐induced distortions for MRIgRT T Stanescu, K Wachowicz, DA Jaffray Medical Physics 39 (12), 7185-7193, 2012 | 120 | 2012 |
A facility for magnetic resonance–guided radiation therapy DA Jaffray, MC Carlone, MF Milosevic, SL Breen, T Stanescu, A Rink, ... Seminars in radiation oncology 24 (3), 193-195, 2014 | 107 | 2014 |
Investigation of a 3D system distortion correction method for MR images T Stanescu, HS Jans, K Wachowicz, BG Fallone Journal of applied clinical medical physics 11 (1), 200-216, 2010 | 74 | 2010 |
TU‐C‐M100F‐01: development of a linac‐MRI system for real‐time ART B Fallone, M Carlone, B Murray, S Rathee, T Stanescu, S Steciw, ... Medical Physics 34 (6Part17), 2547-2547, 2007 | 72 | 2007 |
Magnetic field effects on the energy deposition spectra of MV photon radiation C Kirkby, T Stanescu, BG Fallone Physics in Medicine & Biology 54 (2), 243, 2008 | 39 | 2008 |
3T MR-based treatment planning for radiotherapy of brain lesions T Stanescu, J Hans-Sonke, P Stavrev, BG Fallone Radiology and Oncology 40 (2), 2006 | 39 | 2006 |
Implications of tissue magnetic susceptibility‐related distortion on the rotating magnet in an MR‐linac design K Wachowicz, T Stanescu, SD Thomas, BG Fallone Medical physics 37 (4), 1714-1721, 2010 | 37 | 2010 |
Integration of quantitative imaging biomarkers in clinical trials for MR-guided radiotherapy: Conceptual guidance for multicentre studies from the MR-Linac Consortium Imaging … PJ van Houdt, H Saeed, D Thorwarth, CD Fuller, WA Hall, BA McDonald, ... European Journal of Cancer 153, 64-71, 2021 | 32 | 2021 |
Harmonic analysis for the characterization and correction of geometric distortion in MRI T Tadic, DA Jaffray, T Stanescu Medical physics 41 (11), 112303, 2014 | 30 | 2014 |
Stereotactic body radiation therapy for hepatocellular carcinoma: From infancy to ongoing maturity S Lewis, L Dawson, A Barry, T Stanescu, I Mohamad, A Hosni JHEP Reports 4 (8), 100498, 2022 | 29 | 2022 |
MRI-based upper abdominal organs-at-risk atlas for radiation oncology J Lukovic, L Henke, C Gani, TK Kim, T Stanescu, A Hosni, P Lindsay, ... International Journal of Radiation Oncology* Biology* Physics 106 (4), 743-753, 2020 | 27 | 2020 |
Lag measurement in an active matrix flat‐panel imager C Schroeder, T Stanescu, S Rathee, BG Fallone Medical Physics 31 (5), 1203-1209, 2004 | 24 | 2004 |
MRI-guided online adaptive stereotactic body radiation therapy of liver and pancreas tumors on an MR-linac system T Stanescu, A Shessel, C Carpino-Rocca, E Taylor, O Semeniuk, W Li, ... Cancers 14 (3), 716, 2022 | 23 | 2022 |
Patient alignment in MRI guided radiation therapy J Winter, M Westmore, M Dahan, L Petropoulos, B Guyot, DA Jaffray, ... US Patent App. 13/778,621, 2013 | 23 | 2013 |
Emerging technologies in brachytherapy WY Song, K Tanderup, B Pieters CRC press, 2017 | 22* | 2017 |
Sensitivity reduction in biased amorphous selenium photoconductors S Steciw, T Stanescu, S Rathee, BG Fallone Journal of Physics D: Applied Physics 35 (21), 2716, 2002 | 22 | 2002 |
Method and apparatus for the measurement, characterization and correction of geometric distortions in magnetic resonance imaging T Tadic, TM Stanescu US Patent 9,857,443, 2018 | 17 | 2018 |