Steady-state heat conduction in multi-layer bodies A Haji-Sheikh, JV Beck, D Agonafer International Journal of Heat and Mass Transfer 46 (13), 2363-2379, 2003 | 135 | 2003 |
A brief overview of recent developments in thermal management in data centers S Alkharabsheh, J Fernandes, B Gebrehiwot, D Agonafer, K Ghose, ... Journal of Electronic Packaging 137 (4), 040801, 2015 | 122 | 2015 |
Convertible cooling module for air or water cooling of electronic circuit components D Agonafer, TM Anderson, GM Chrysler, RCF Chu, RE Simons, DT Vader US Patent 5,370,178, 1994 | 114 | 1994 |
Isothermal heat sink with tiered cooling channels D Agonafer, RC Chu, MJ Ellsworth Jr, RE Simons US Patent 6,337,794, 2002 | 106 | 2002 |
Optimization of data center room layout to minimize rack inlet air temperature S Bhopte, D Agonafer, R Schmidt, B Sammakia | 101 | 2006 |
The LVEL turbulence model for conjugate heat transfer at low Reynolds numbers D Agonafer, L Gan-Li, DB Spalding ASME International Mechanical Engineering Congress and Exposition 15533, 23-26, 1996 | 86 | 1996 |
Cavity plate and jet nozzle assemblies for use in cooling an electronic module, and methods of fabrication thereof D Agonafer, RC Chu, MJ Ellsworth Jr, RE Simons US Patent 6,431,260, 2002 | 83 | 2002 |
Effects of mineral oil immersion cooling on IT equipment reliability and reliability enhancements to data center operations JM Shah, R Eiland, A Siddarth, D Agonafer 2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical …, 2016 | 65 | 2016 |
Convertible heat exchanger for air or water cooling of electronic circuit components and the like D Agonafer, TM Anderson, GM Chrysler, RC Chu, RE Simons, DT Vader US Patent 5,482,113, 1996 | 60 | 1996 |
Effect of under floor blockages on data center performance S Bhopte, B Sammakia, R Schmidt, MK Iyengar, D Agonafer Thermal and Thermomechanical Proceedings 10th Intersociety Conference on …, 2006 | 54 | 2006 |
Flow Rate and inlet temperature considerations for direct immersion of a single server in mineral oil R Eiland, J Fernandes, M Vallejo, D Agonafer, V Mulay Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena …, 2014 | 49 | 2014 |
A simulation-based multi-objective design optimization of electronic packages under thermal cycling and bending L Xu, T Reinikainen, W Ren, BP Wang, Z Han, D Agonafer Microelectronics Reliability 44 (12), 1977-1983, 2004 | 46 | 2004 |
Numerical modeling of forced convection heat transfer for modules mounted on circuit boards D Agonafer, DF Moffatt | 42 | 1990 |
Thermal performance and efficiency of a mineral oil immersed server over varied environmental operating conditions R Eiland, J Edward Fernandes, M Vallejo, A Siddarth, D Agonafer, ... Journal of Electronic Packaging 139 (4), 041005, 2017 | 38 | 2017 |
Effect of relative humidity, temperature and gaseous and particulate contaminations on information technology equipment reliability P Singh, L Klein, D Agonafer, JM Shah, KD Pujara International Electronic Packaging Technical Conference and Exhibition 56888 …, 2015 | 36 | 2015 |
Reliability considerations for oil immersion-cooled data centers JM Shah, R Eiland, P Rajmane, A Siddarth, D Agonafer, V Mulay Journal of Electronic Packaging 141 (2), 021007, 2019 | 35 | 2019 |
Thermo-mechanical challenges in stacked packaging D Agonafer, A Kaisare, MM Hossain, Y Lee, BP Dewan-Sandur, ... Heat Transfer Engineering 29 (2), 134-148, 2008 | 35 | 2008 |
Air flow distribution in integrated circuit spot coolers D Agonafer, TM Anderson, GM Chrysler, RE Simons US Patent 5,704,419, 1998 | 34 | 1998 |
Measurement of the thermal performance of a custom-build single-phase immersion cooled server at various high and low temperatures for prolonged time PV Bansode, JM Shah, G Gupta, D Agonafer, H Patel, D Roe, R Tufty Journal of Electronic Packaging 142 (1), 011010, 2020 | 33 | 2020 |
Thermal Model of a PC RL Linton, D Agonafer | 33 | 1994 |