Individualised, micro CT-based finite element modelling as a tool for biomechanical analysis related to tissue engineering of bone SVN Jaecques, H Van Oosterwyck, L Muraru, T Van Cleynenbreugel, ... Biomaterials 25 (9), 1683-1696, 2004 | 232 | 2004 |
Influence of implant connection type on the biomechanical environment of immediately placed implants–CT‐based nonlinear, three‐dimensional finite element analysis RS Pessoa, L Muraru, EM Júnior, LG Vaz, JV Sloten, J Duyck, ... Clinical implant dentistry and related research 12 (3), 219-234, 2010 | 214 | 2010 |
Trabecular bone strains around a dental implant and associated micromotions—A micro-CT-based three-dimensional finite element study G Limbert, C van Lierde, OL Muraru, XF Walboomers, M Frank, ... Journal of biomechanics 43 (7), 1251-1261, 2010 | 112 | 2010 |
Resonance frequency analysis of implants in the guinea pig model: influence of boundary conditions and orientation of the transducer V Pattijn, SVN Jaecques, E De Smet, L Muraru, C Van Lierde, ... Medical engineering & physics 29 (2), 182-190, 2007 | 87 | 2007 |
Gait assessment during the initial fitting of customized selective laser sintering ankle foot orthoses in subjects with drop foot V Creylman, L Muraru, J Pallari, H Vertommen, L Peeraer Prosthetics and orthotics international 37 (2), 132-138, 2013 | 76 | 2013 |
Design and additive fabrication of foot and ankle-foot orthoses JHP Pallari, KW Dalgarno, J Munguia, L Muraru, L Peeraer, S Telfer, ... University of Texas at Austin, 2010 | 59 | 2010 |
Influence of implant design on the biomechanical environment of immediately placed implants: computed tomography-based nonlinear three-dimensional finite element analysis. RS Pessoa, PG Coelho, L Muraru, E Marcantonio Jr, L Geraldo Vaz, ... International Journal of Oral & Maxillofacial Implants 26 (6), 2011 | 52 | 2011 |
Effectiveness of robotic exoskeletons for improving gait in children with cerebral palsy: A systematic review M Hunt, L Everaert, M Brown, L Muraru, E Hatzidimitriadou, K Desloovere Gait & Posture 98, 343-354, 2022 | 12 | 2022 |
Three-dimensional finite element models based on in vivo microfocus computed tomography: elimination of metal artefacts in a small laboratory animal model by registration with … L Muraru, C Van Lierde, I Naert, J Vander Sloten, SVN Jaecques Advances in Engineering Software 40 (11), 1207-1210, 2009 | 9 | 2009 |
SLS Nylon 12 Characterization Through Tensile Testing and Digital Image Correlation for Finite Element Modeling of Food and Ankle-Foot Orthoses L Muraru, J Pallari, V Creylman, J Vander Sloten, L Peeraer University of Texas at Austin, 2010 | 7 | 2010 |
Evaluation of the influence of cyclic loading on a laser sintered transtibial prosthetic socket using Digital Image Correlation (DIC) T Saey, L Muraru, E De Raeve, K Cuppens, R Balcaen, V Creylman 2019 41st Annual International Conference of the IEEE Engineering in …, 2019 | 5 | 2019 |
The use of a robotic gait simulator for the development of an alignment tool for lower limb prostheses E De Raeve, T Saey, L Muraru, L Peeraer Journal of Foot and Ankle Research 7 (1), 1-2, 2014 | 5 | 2014 |
In vivo micro-CT-based FE models of guinea pigs with titanium implants: an STL-based approach SVN Jaecques, L Muraru, C Van Lierde, E De Smet, H Van Oosterywck, ... International Congress Series 1268, 579-583, 2004 | 5 | 2004 |
Rehabilitation supported by technology: protocol for an international cocreation and user experience study S Bernaerts, NAJ De Witte, V Van der Auwera, B Bonroy, L Muraru, ... JMIR Research Protocols 11 (3), e34537, 2022 | 4 | 2022 |
Validation of ankle foot orthosis finite element models by optical strain measurements L Muraru, V Creylman, J Pallari, R Willemsen, J Vander Sloten, L Peeraer Proceedings of the 9th International Symposium Computer Methods in …, 2010 | 4 | 2010 |
Avaliação biomecânica de implantes imediatos com carga imediata: análise 3D em elementos finitos RS Pessoa, L Muraru, LG Vaz, E Marcantonio Júnior, JV Sloten, ... Innov. implant. j., biomater. esthet.(Impr.), 10-16, 2009 | 4 | 2009 |
Micro CT-based finite elemente analysis: an enhanced follow-up tool for bone remodelling around threaded implants. SVN Jaecques, L Muraru, E De Smet, H Van Oosterwyck, M Wevers, ... CARS, 1356, 2003 | 4 | 2003 |
Using a texture analyser to objectively quantify foot orthoses K Cuppens, E De Raeve, T Saey, M Broeckx, I Knippels, J Claes, ... 2019 41st Annual International Conference of the IEEE Engineering in …, 2019 | 3 | 2019 |
Influência do desenho do implante na micromovimentação de implantes imediatos com carga imediata: análise multivariada em elementos finitos RS Pessoa, L Muraru, LG Vaz, GN Pereira, JV Sloten, SVN Jaecques Innov. implant. j., biomater. esthet.(Impr.), 44-49, 2010 | 3 | 2010 |